Products
Mechanical and pneumatic rapping systems
Salzgitter Kesselservice offers mechanical and pneumatic rapping systems for cleaning suspended heating surfaces in horizontal boiler passes. The design is selected according to the boiler, fuel, cleaning task and installation conditions.
- For horizontal boiler passes
- Cleaning by impact energy, without cleaning medium
- Made in Germany

The system
How rapping systems clean
In horizontal boiler passes of waste incineration plants and biomass power plants, rapping devices clean evaporators, superheaters and economizers. The bottoms of the horizontal boiler headers are rapped pneumatically or mechanically. The impulse on the vertically suspended heating surfaces loosens the deposits from the tubes, without additional cleaning media.
With over 20 years of experience in optimizing existing rapping systems, we have been offering our own rapping devices for 10 years, manufactured entirely in Salzgitter.
Advantages of our rapping systems
- Robust and durable design.
- Optimized ram guide counteracts jamming of the rams.
- Design for effective transfer of the impact energy to the heating surfaces.
- Control of the rapping sequences according to the selected design.
Three designs
-
Individual rapper EKL
Each boiler header has its own impact cylinder, which can be controlled individually.
-
Pneumatic rapping carriage PKL
One or two impact cylinders on an electrically driven carriage clean a complete area.
-
Mechanical rapping system MKL
Drop hammers on an electrically driven, rotating shaft generate the cleaning impulses.
Frequently asked questions about rapping systems
Where are rapping systems used?
In horizontal boiler passes with suspended tube bundles, for example on evaporators, superheaters and economizers in waste incineration plants and biomass power plants.
How do rapping systems clean?
Both variants clean with mechanical impact energy. Mechanical rapping systems generate it with drop hammers, pneumatic rapping systems with compressed-air-operated impact cylinders. The transmitted impulses loosen deposits from the suspended heating surfaces.
Do rapping systems need sound insulation?
Yes, sound insulation is always necessary.
Can rapping systems be used in outdoor plants?
Yes, with a suitable enclosure.
What is the advantage of rapping systems?
A simple design and easy maintenance. No additional cleaning media such as steam, air or water are needed.
Which rapping system designs does SZKS offer?
The range comprises mechanical rapping devices MKL, pneumatic rapping devices with individual rappers EKL and pneumatic rapping devices with rapping carriage PKL.
Planning a plant or need advice?
Send us the key data of your boiler, or call us. We advise independently of manufacturers and prepare a quote for you.
Talk to us directly
+49 5341 9017412